Radiator Output Equation:
| From: | To: |
The Radiator Output Calculator estimates the thermal output of radiators based on temperature difference and specific factor values. This calculation is essential for proper heating system design and radiator sizing in UK buildings.
The calculator uses the radiator output equation:
Where:
Explanation: The equation accounts for the non-linear relationship between temperature difference and heat output, with the 1.3 exponent reflecting real-world radiator performance characteristics.
Details: Accurate radiator output calculation is crucial for designing efficient heating systems, ensuring proper room temperatures, optimizing energy consumption, and selecting appropriately sized radiators for different spaces.
Tips: Enter temperature difference in Kelvin and the radiator factor in W/K1.3. Both values must be positive numbers. Typical temperature differences range from 30K to 50K for standard heating systems.
Q1: What is ΔT in radiator calculations?
A: ΔT (Delta T) is the difference between the mean water temperature in the radiator and the desired room temperature, measured in Kelvin.
Q2: How do I find the factor value for my radiator?
A: The factor value is typically provided by radiator manufacturers in their technical specifications or product datasheets.
Q3: Why is the exponent 1.3 used?
A: The 1.3 exponent reflects the real-world heat transfer characteristics of radiators, accounting for both convection and radiation heat transfer modes.
Q4: What are typical ΔT values for UK heating systems?
A: Standard UK heating systems typically operate with ΔT values between 40K and 50K, though low-temperature systems may use lower values.
Q5: Can this calculator be used for underfloor heating?
A: No, this calculator is specifically designed for radiators. Underfloor heating systems have different heat output characteristics and require separate calculations.